Learning you need a back up generator is often something you learn the hard way, especially when you need it for your business. Amid the concerns a business presents daily, the threat of a power outage to daily business usually isn't one of them. But when a power outage bathes your facility in black, you remember something you've needed all along: an emergency back up generator. Minor power outages are common occurrences for businesses and organizations worldwide. But when an outage lasts longer than three hours, you're looking at losing a half a day of business due to something that's preventable. But you probably have some questions before you buy a generator, beginning with what type of generator is right for your building.
Consulting a Generator Services Company about Your Generator Needs
When you consult with a generator services company, you'll discover that the type of generator you need depends on at least three factors: the size of your building, how long you'd like to maintain power in the event of an outage, and, ultimately, whether your business is one that requires uninterrupted power supply or can deal with briefly de-accessing from commercial power before accessing generator power. We take a look at these factors below.
1. The Size of your Building
Because commercial generators usually run on natural gas or diesel fuel, their fuel reservoir partially determines their size, with bigger generators usually appearing in bigger buildings. If your building is small to midsized and most of its electricity goes toward lighting and HVAC support (which is the case with most commercial buildings), a single commercial grade generator should more than serve your need.
2. How long you'd like to maintain Power in the Event of an Outage
Purchasing a generator that can supply your building with 16-20 hours of power is the safest option. If the power company can't fix the problem on the first day, you can still do business on the second day of an outage. How long your building retains power will ultimately depend on its electricity needs in relation to a generator's fuel reservoir. For example, a large, industrial grade generator can keep an average sized hospital in operation for 8 hours. But applying such a generator to a smaller structure could result in a supply of electricity that lasts over a week.
3. The Nature of your Power Supply Needs
The nature of your power supply needs deals with what model of generator you'll install: one whose transfer switch operates on a break before make basis, in which commercial power is de-accessed before generator power is accessed; or one whose transfer switch operates on a make before break basis, in which the opposite occurs. Examples of outfits that require make before make are hospitals, data centers, laboratories, and defense organizations, which require uninterrupted power supply due to critical functions.
In my research on power switch maintenance, I've studied the importance of transfer switch maintenance to generator function.
|
|
Transfer Switch $70.1 High Quality Content by WIKIPEDIA articles Transfer switches allow switching from a primary power source to a secondary or tertiary power source and are employed in some electrical power distribution systems. Most often transfer switches can be seen where emergency power generators are used to back up power from the utility source. The transfer switch allows safely switching from utility power to emergency generator power while maintaining isolation of each source from the other. The switch may be either a manual switch, an automatic switch, or a combination of manual and automatic. In a home during a power outage, for example, the transfer switch allows isolation of the owners critical circuits (e.g. cooling, refrigerator, lighting) from the utility service, allowing for operation of the generator without backfeeding to the utility, which can damage utility equipment and hurt (or kill) utility workers. Author: Surhone, Lambert M./ Timpledon, Miriam T./ Marseken, Susan F. Binding Type: Paperback Number of Pages: 78 Publication Date: 2010/07/22 Language: English Dimensions: 6.00 x 9.02 x 0.19 inches |
|
|
Hardware Express 660056 Automatic Transfer Switch for Generator Ready Loadcenter $470.92 100A. For Automatic Standby Generators. Operates Automatically When Connected To Generator. Transfers Load From Utility To Generator And Back To Utility. |
|
|
Briggs and Stratton 40303B-46 15kW Automatic Standby Generator System Package with 200 Amp House Managing Transfer Switch $4289.99 15kW Automatic Standby Home Generator System - 40303B. 200 Amp House Management Transfer Switch - 71046. Hour Meter. Battery Charger. Polymer Installation Pad |
|
|
Briggs and Stratton 40305B-46 20kW Automatic Standby Generator System Package with 200 Amp House Managing Transfer Switch $4789.99 20kW Air Cooled Automatic Standby Home Generator System - 40305B. 200 Amp House Management Transfer Switch - 71046. Hour Meter. Battery Charger. Polymer Installation Pad |
|
|
Briggs and Stratton 40325-46 10kW Automatic Standby Generator System Package with 200 Amp House Managing Transfer Switch $3489.99 10kW Automatic Standby Home Generator System - 40325. 200 Amp House Management Transfer Switch - 71046. Hour Meter. Battery Charger. Polymer Installation Pad |
|
|
Briggs and Stratton 40326-47 12kW Automatic Standby Home Generator System with 100 Amp 16 Circuit Transfer Switch $3489.99 12kW Automatic Standby Home Generator System - 40326. 100 Amp 16 Circuit Transfer Switch - 71047. Hour Meter. Battery Charger. Polymer Installation Pad |
|
|
Briggs and Stratton 40326-45 12kW Automatic Standby Generator System Package with 100 Amp House Managing Transfer Switch $3589.99 12kW Automatic Standby Home Generator System - 40326. 100 Amp House Management Transfer Switch - 71045. Hour Meter. Battery Charger. Polymer Installation Pad |
|
|
Briggs and Stratton 40303B-45 15kW Automatic Standby Generator System Package with 100 Amp House Managing Transfer Switch $4189.99 15kW Automatic Standby Home Generator System - 40303B. 100 Amp House Management Transfer Switch - 71045. Hour Meter. Battery Charger. Polymer Installation Pad |
|
|
Briggs and Stratton 40303B-47 15kW Automatic Standby Home Generator System with 100 Amp 16 Circuit Transfer Switch $4089.99 15kW Automatic Standby Home Generator System - 40303B. 100 Amp 16 Circuit Transfer Switch - 71047. Hour Meter. Battery Charger. Polymer Installation Pad |
|
|
Briggs and Stratton 40325-47 10kW Automatic Standby Home Generator System with 100 Amp 16 Circuit Transfer Switch $3289.99 10kW Automatic Standby Home Generator System - 40325. 100 Amp 16 Circuit Transfer Switch - 71047. Hour Meter. Battery Charger. Polymer Installation Pad |
|
|
Briggs and Stratton 40301A-18 7kW Automatic Standby Home Generator System with 50 Amp 10 Circuit Transfer Switch $2319.99 7kW Automatic Standby Home Generator System - 40301A. 50 Amp 10 Circuit Transfer Switch - 1918. Hour Meter. Battery Charger. Polymer Installation Pad |
|
|
Briggs and Stratton 40326-46 12kW Automatic Standby Generator System Package with 200 Amp House Managing Transfer Switch $3689.99 12kW Automatic Standby Home Generator System - 40326. 200 Amp House Management Transfer Switch - 71046. Hour Meter. Battery Charger. Polymer Installation Pad |
|
|
Briggs and Stratton 40305B-45 20kW Automatic Standby Generator System Package with 100 Amp House Managing Transfer Switch $4689.99 20kW Air Cooled Automatic Standby Home Generator System - 40305B. 100 Amp House Management Transfer Switch - 71045. Hour Meter. Battery Charger. Polymer Installation Pad |
|
|
Briggs and Stratton 40325-45 10kW Automatic Standby Generator System Package with 100 Amp House Managing Transfer Switch $3389.99 10kW Automatic Standby Home Generator System - 40325. 100 Amp House Management Transfer Switch - 71045. Hour Meter. Battery Charger. Polymer Installation Pad |
|
|
Egsu200Nseaca - Eaton Automatic Transfer Switch - 2 Poles $1004.88 Eaton's GREEN Automatic Transfer Switches (ATS), when used in conjunction with a standby generator, guarantee reliable, seamless power when outages occur. They automatically transfer the load to the generator when utility power fails, providing the highest protection for continuous power. Eaton's GREEN ATS provides a unique and truly active load management system which intelligently manages loads. By using this technology, consumers can maximize the output of the generator, reduce upfront costs, reduce fuel consumption, and reduce greenhouse gas emissions; a truly environmentally-friendly transfer switch. [ND8146] UNSPC: 39121100 29.33L x 14.46W x 5.32H 45 LB |
|
|
Egsu100Nseaca - Eaton Automatic Transfer Switch - 2 Poles $616.54 Eaton's GREEN Automatic Transfer Switches (ATS), when used in conjunction with a standby generator, guarantee reliable, seamless power when outages occur. They automatically transfer the load to the generator when utility power fails, providing the highest protection for continuous power. Eaton's GREEN ATS provides a unique and truly active load management system which intelligently manages loads. By using this technology, consumers can maximize the output of the generator, reduce upfront costs, reduce fuel consumption, and reduce greenhouse gas emissions; a truly environmentally-friendly transfer switch. [ND5935] UNSPC: 39121100 x 14.5W 28 LB |
|
|
Uts6H - Apc Automatic Transfer Switch $385.66 the Apc Universal Transfer Switch (uts) Monitors The Utility Power Conditions of Your Home or Small Business And Safely Transfers Loads to Two Backup Power Sources When a Power Disturbance Occurs. Power is Conveniently Distributed From The Backup Sources to as Many as Ten Circuits, Keeping Critical Loads Such as Lights, Furnaces, Well Pumps, And Home Appliances up And Running During an Outage. Unlike Other Transfer Switches That Are Compatible Only With Generators, The Uts Can Also be Connected to a Ups. As a Result of This Unique Feature, Your Most Important Loads Will Remain Uninterrupted And Conditioned During That Critical Time Between a Power Failure And Generator Start-up. The Uts Also Incorporates Patent-pending Adaptive Load Management Technology (alm) Which Intelligently Monitors Power Usage And Automatically Sheds And Reconnects Loads in Order to Prevent Generator Overload. All Apc Universal Transfer Switches Comply With The UL 1008 Transfer Switch Standard, Giving You Peace of Mind During Installation And Operation. [U44202] UPC: 731304264514 UNSPC: 39121100 23L x 19W x 8.9H 24 LB 2.42 Cubes |
|
|
5870 - 8/7Kw Air Cooled Stand By Generator, Comes With Transfer Switch $2626.16 [111851] Truck Delivery UPC: 696471058703 48L x 25W x 29H 336 LB |
|
|
All Power Supply GPTS 30 Amp Transfer Switch Quick Connect $341 The Go Power prewired 30 amp automatic transfer switch is used to hardwire power inverters into a system where there is an alternative source of AC already present for example a generator or utility power. This 30 amp transfer switch is made to only allow one source of AC power to pass through it to your loads. This ensures that your power inverter will not be damaged if the generator or utility power is hooked up while the power inverter is running. The GPTS is prewired for a quick and easy installation to your existing system whether it is an RV marine or cottage application. The GPTS also includes a 15 amp outlet on the side that is only powered by shore power or generator allowing you to hook up a battery charger without worrying about the inverter running the charger. |
|
|
Generac 5875 Guardian Series Air-Cooled 20kW 120/240 Volt Single Phase Aluminum Residential Generator with RTS Transfer Switch $4497 200 Amp Service Entrance Rated 120/240 Single Phase RTS Transfer Switch For 22-60 kW Generators(GRCNRTSD200A3). 1-ft Flexible Fuel Line Connector. Composite Mounting Pad. Instruction Sheets |
|
|
Generac 5837 Core Power 7kW 120/240 Volt Single Phase Air-Cooled Standby Generator with EZ Transfer Switch $1861 8 Circuit EZ Switch With Built-In Load Center. 1-ft Flexible Fuel Line Connector. Composite Mounting Pad. Instruction Sheets |
|
|
Transfer Case Vacuum Switch Seal $1.99 Transfer Case Vacuum Switch Seal; |
|
|
Generac 5447 EZ Transfer Operator Field Installation Kit $203 EZ Transfer Operator. 15A Double Pole Breaker for Generator Sensing Circuit. 125A Lower Panel, Generator Circuit Switch. Hold Down Bracket. Interlock Bar. Mounting Hardware. Decals. Instruction Sheets |
|
|
Generator $9.49 Generator |
|
|
Automatic Transfer Switch redundant switch $886.99 APC Automatic Transfer Switch - Redundant switch ( rack-mountable ) - AC 120/208 V - 1 output connector(s) - 1U - 19" |
|
|
Generac 5872 Guardian Series Air-Cooled 14kW 120/240 Volt Single Phase Steel Residential Generator with EZ Transfer Switch $3292 14 Circuit EZ Switch With Built-In Load Center (GRCNRTS14EZA1). 1-ft Flexible Fuel Line Connector. Composite Mounting Pad. Instruction Sheets |
|
|
Generac 5873 Guardian Series Air-Cooled 17kW 120/240 Volt Single Phase Steel Residential Generator with EZ Transfer Switch $3694 16 Circuit EZ Switch With Built-In Load Center (GRCNRTS16EZA1). 1-ft Flexible Fuel Line Connector. Composite Mounting Pad. Instruction Sheets |
|
|
Generac 5870 Guardian Series Air-Cooled 8kW 120/240 Volt Single Phase Steel Residential Generator with EZ Transfer Switch $2204 10 Circuit EZ Switch With Built-In Load Center (GRCNRTS10EZA1). 1-ft Flexible Fuel Line Connector. Composite Mounting Pad. Instruction Sheets |
|
|
Generac 5871 Guardian Series Air-Cooled 10kW 120/240 Volt Single Phase Steel Residential Generator with EZ Transfer Switch $2792 12 Circuit EZ Switch With Built-In Load Center (GRCNRTS12EZA1). 1-ft Flexible Fuel Line Connector. Composite Mounting Pad. Instruction Sheets |
|
|
Generac 5449 NEMA 1 GenReady Advanced Load Center with EZ Transfer Operator $391 EZ Transfer Operator. 125A Lower Panel Circuit Switch. 15A Double Pole Breaker for Generator Sensing Circuit. Instruction Sheets |
|
|
Generac 5454 NEMA 3R GenReady Advanced Load Center with EZ Transfer Operator $440 EZ Transfer Operator. 125A Lower Panel Circuit Switch. 15A Double Pole Breaker for Generator Sensing Circuit. Instruction Sheets |
|
|
Rack Automatic Transfer Switch redundant switch $976.99 APC Rack Automatic Transfer Switch - Redundant switch ( rack-mountable ) - AC 120 V - Ethernet RS-232 - 16 output connector(s) - 2U |
|
|
All Power Supply STS30 Transfer Switch with Inverter Quick Connect 30 Amps $305.49 Has a rated capacity of 30 Amps at 120 VAC and is suitable for a 30 Amp Utility Power Cord and a Generator of up to 3.6 KVA capacity. Uses a heavy duty Double Pole Double Throw (DPDT) relay for switching both the Line and Neutral. Can be installed on the line side of the main breaker panel allowing switching of the entire load or on the load side to only switch dedicated circuits. DIP Switch select to enable a time delay when transferring to a generator. Comes with a standard North American power cord for convenient connection to 15 Amp NEMA515R receptacles on a generator or an inverter with up to 1800 VA capacity (Replace this cord with 30 Amp cord if full 30 Amp capacity is required). Input / output voltage: 120 VAC 60 Hz. Input / output current: 30 A. Battery charger receptacle: Dual NEMA515R 5 A max 12 A continuous Fused at 15 A. Knockouts: for 1 and _ . Maximum operatin g time of the relay : 25 msec. Delay time for generator warm up: 20 sec + / 5 sec. Enabling / disabling of delay time:Yes. With DIP switch SW1 Delay enabled: OFF (1) Delay disabled: ON. Operatin g temperatur E: 0 40oC. |


US $1,939.00